SLA Surface
RANGE / SURFACE

SLA Surface

A multi-layered, microporous surface treatment engineered to bring bone tissue deeper into contact with the implant.

How It Works

Active hydrophilic surface, engineered for osseointegration.

STERILITY

STERILE R

All production of MENTORMED Implants is thoroughly sterilized. Double sterile packing ensures sterility maintenance. Due to a high technical level of production and the strictest control of sterility, MENTORMED Implants meets the requirements of the highest quality standards, confirmed by appropriate certificates.

Positioning of the implant in bone

Positioning of the Implant in Bone

Bone depth on the side of the cortical plate must be not less than 1 mm.

Distance between the implant and tooth root

Distance to the Tooth Root

The distance between an implant and a tooth root must be minimum 1.5 mm: the distance from the implant site center to the next tooth must be about half the implant's diameter, plus 1.5 mm.

Distance between two implants

Implant to Implant

The distance between two implants must be a sum of half the diameters of the implant bodies installed, plus 3 mm.

Surface Technology

SLA Surface

SLA Surface represents the latest generation of dental implant surface treatment technology. This surface is active and hydrophilic; it has a distinct multi-layered microporous structure. The thickness of the oxide layer of the implant surface reaches 10 to 12 microns. The entire thickness of the oxide layer is imbued with micro-pores that combine with each other and create a multi-layered surface.

This way, the bone tissue grows deeper both in and between micro-pores. Thereby, implant surface area is significantly increased and, thus, the contact between bone tissue and implant surface is strengthened. Titanium oxide film is enriched with calcium hydroxyapatite, and the implant surface is contaminant-free. It has prominent hydrophilic characteristics (absorption).

MentorMed SLA implant surface, micrograph
Clinical Result

Faster stability, earlier rehabilitation.

Research shows that the SLA Surface stimulates active bone growth over the implant surface, resulting in mechanical stability. This property allows orthopedic rehabilitation to happen at an earlier stage, and significantly reduces risk when the implant is installed under a one-stage procedure.

Also in the Range

Explore the rest of the system.

MentorMed Implant
Range / Implant

MentorMed Implant

Seven engineering decisions run from platform to apex, tested for stability, bone contact, and long-term integration.

Platform switching prevents cortical compression
Micro thread for closer cortical contact
Active thread for stability in soft bone
Antirotational sulcus locks the fit
Know More →
Accessories
Range / Restorative

Accessories

Every compatible part your clinic runs on daily: abutments, healing caps, impression components and screws.

Cover screw included with every implant
Titanium & PEEK abutments, straight and angulated
Narrow, wide and multi-unit healing caps
Open and closed-tray impression copings
Know More →
Surgical Kit
Range / Surgical

Surgical Kit

Diamond-like coated drills sequenced for a precise, predictable bone cavity, matched to implant diameter and bone type.

Drill diameters from 1.5mm to 6.0mm
Sequential protocol per bone type I to IV
Manual and ratchet torque control
Organized, sterilizable kit tray
Know More →